EMC seminar
30
Some modern analyzers approach accuracy of power meter + sensor
Even better for low-level signals, with narrower noise bandwidth and
the benefit of frequency selectivity
Some factors determining uncertainty:
• Input connector (mismatch)
• RF input attenuator
• Mixer and input filter (flatness)
• IF gain/attenuation (reference level)
• RBW filters
• Display scale fidelity
• Calibrator
Modern Spectrum Analyzer Accuracy