Evolution Technologies 225c Guía para resolver problemas Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 14
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
ElectricalSignalingToolsComparison
125 215C 225C
Display
Monochrome Color
Inputs
2 Scope & Dual DMM 2 Scope & DMM
Bandwidth
40 MHz 100 MHz 200 MHz
Sample Rate
25 MSa/s Real time, 5 GSa/s Equivalent time 1 GSa/s 2.5 GSa.s
Bus Health
3 3 3
Bus Health with Noise Measurements
-
3 3
Bus Health Connection Diagrams
-
3 3
TrendPlot ™
3 3 3
ScopeRecord ™
-
3 3
100 Screen Replay
-
3 3
Battery
7 Hr NiMH 4 hr NiMH
Isolated Inputs
No CATII 1000V, CATIII 600V
Safety Rating
CATIII 600V CATII 1000V, CATIII 600V
Designed For
Electrical and electro-mechanical systems &
industrial bus diagnostics
Electrical, electro-mechanical and electronic troubleshooting,
waveform analysis and bus health analysis and troubleshooting
ScopeMeterTestTools
Industrial network physical layer signal test
ScopeMeter test tools are designed for troubleshooting industrial
machinery and the industrial network connecting machinery. Today’s
industrial plant control and manufacturing processes are connected via
a digital network.
Determining if a network problem is with the cabling, electrical
signaling, or the digital protocol is critical. Use the ScopeMeter 125,
215C or 225C to verify the electrical integrity of a plant’s digital
network signaling, perform ‘physical layer tests’ and get answers
quickly and easily.
The Fluke 125, 215C and 225C simplify the task of troubleshooting
networks by adding automatic physical layer signal measurement plus:
The Fluke 125, 215C and 225C
Validate signal integrity on multiple -
types of industrial networks
Capture signal disturbances, -
anomalies and display induced noise
Compare critical measurement -
against industry standards for
easy go/no-go results
The Fluke 125
A cost effective tool for electrical & electro-mechanical plus -
bus health test
The 225C and 215C
Performance oscilloscope for industrial electronic and electrical -
equipment plus bus health troubleshooting.
Gives more-extensive industrial bus signal analysis capabilities -
Isolated inputs for differential measurements -
The ScopeMeter is used to:
Obtain quantitative measurement results to isolate network
communication problems to signal amplitude, attenuation,
data rate/timing or signal noise, distortion or jitter.
Eliminate the guesswork or signal analysis and complex interpre-
tation by comparing measurement values to industry standards
Use the clear Go/No-go indicators to simplify troubleshooting
Use the eye pattern display mode for easy to view qualitative
signal analysis, displaying extent of noise or signal disturbances
Fully isolated inputs for true differential signal measurements
Fluke771MilliampProcessClampMeter
Don’t break the loop on 4 mA to 20 mA signal
measurements
Use the 771 mA Clamp Meter for PLC and
control systems analog I/O. The detachable clamp
with extension cable allows you to take measure-
ments in tight locations. The 771 is used to:
Measure mA signal for PLC and control
system analog I/O
Measure 4 mA to 20 mA output signals from
transmitters without breaking the loop.
Measure mA signals with 0.01 mA resolution
ElectricalSignalingTools
Vista de pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14

Comentarios a estos manuales

Sin comentarios